• Sourcing Solutions
  • Services & Membership
  • Help & Community

Quick Details

  • Place of Origin: Henan, China (Mainland)
  • Brand Name: JINYU
  • Model Number: JY-TR13020108
  • Usage: Industrial, measuring the temperature of the molten metal
  • Theory: Temperature Sensor
  • Accuracy: grade 1
  • Temperature range: -200C~500C
  • Type: armored
  • Dimensions: 100-2500mm
  • feature: shock-proof
  • Graduation: Pt100, Pt10, Cu50, Cu100
  • Connection type: Multiple choice
  • Thermal response time: ≤10s
  • Shipping type: By DHL ,Fedex ,Air ,Sea
  • Package: wooden case

Packaging & Delivery

Packaging Details Plastic paper inside, Polyfoam filled, Wooden box outside
Delivery Time 5-15days

Armored thermal resistance sensor       

It is usually connected with display meter, recording meter and computer, etc. to directly measure temperature of liquid vapor gas and solid surface ranging from -200-500 with explosives such as hydrocarbon on production spot.

  

Operation Theory

t is based on that temperature change of material results in change of its resistance .When resistance value changes .the working instrument will display relevant temperature.

 

Filament Diameter& Material

Filament

Simplex

duplex

Tube Diameter

Φ3Φ4Φ5Φ6Φ8

Φ4Φ5Φ6Φ8

Tube material

1Cr 18Ni 9 Ti

1Cr 18Ni 9 Ti

 

Thermal Response Time

Sleeve Tube Diameter

Thermal Response Time

Φ3

<3

Φ4

<5

Φ5

<8

Φ6

<12

Φ8

<15

 

Threaded connector with Fastener

Code & Size

Outer Diameter of Armored Thermal Resistance

Φ8Φ6Φ5

Φ4Φ3

M

Code &Size

M12*1.5

S

22

19

 

Insulation Resistance at Normal Temperature

The insulation resistance between electrode and protection tube of armored thermal resistance shall be no less than 100MΩ under condition that environment temperature 15-35°C ,relative humidity is no more than 80% ,and testing voltage is D.C. 10-100V.

  

Type and specification of thermal resistance sensor

Type

Graduation

Temperature range°C

Thermal response time

Protection tube material

specification

WZP-260

Pt100

0-100

< 30S

1Cr18Ni9Ti

100

150

200

250

300

WZP 2 -260

< 45S

WZP-267M

Pt100

-50-+150

< 30S

WZP-269

Pt100

-200-+300

< 30S

75

100

150

200

250

WZP 2 -269

< 45S

WZC-269

Cu50

-50-+100

<120S

WZP-270

Pt100

-200-+420

< 15S

50

75

100

150

200

WZC-270

Cu50

-50-+150

< 45S

WZP-280

Pt100

-200-+300

< 30S

 

Main technical characteristics :

Category

Platinum resistance

Model

DXW150

Indexing No.

Pt100,Pt1000

Measuring range

-50°C~+600°C

0°C resistance R0

A grade 100±0.06Ω

B grade 100±0.12Ω

Tolerance  value  D°C

A grade ±(0.15+0.002|t|)

B grade ± (0.30+0.005|t|)

Thermal response time

<30s

Minimum Implantation depth

Implantation depth of the minimum thermal resistance/10mm

Dielectric strength

100MΩ/100VDC

Let-through current

≤5mA

Nominal

Generally refers to the working temperature protection tube can withstand without breaking static external pressure.

   

The structure of thermal resistance sensor

It is mainly by the temperature puppet heads and paper tubes.Puppet heads, positive and negative dual wire welding in the compensation wire, wear compensating lead wire embedded in the stent, the stent coat a small paper tube, the thermocouple wire to the quartz support and protection. Outermost fitted with a cap, all components of the anti-residue concentrated load dump adhesion to the refractory filler to form a whole, rather than removable, it is a one-time use.

 

The use of methods 

1, according to the measurement object and scope, select the appropriate protection for the length of the paper tube and the applicable temperature gun.

2, the thermal resistance mounted on the temperature gun record, 

and after that make the secondary instrument pointer (or display) back to zero, then the exposure can be measured.

3.Thermal resistance sensor into the molten steel depth 300-400mm is appropriate, 

when measured not measured on the furnace wall or the scum, so that: fast, stable, accurate, and should be immediately put the gun when the secondary instrument results, fast thermocouple in the molten steel in the soaking time shall not be more than five seconds, or easy to burn the temperature gun.

4, the temperature gun from the furnace, remove the used thermocouple, and install new, pause a few minutes in preparation for the next measurement. Shall not be measured even with the demolition, otherwise caused by temperature fluctuations.

  

Please identify the following items when ordering the thermal resistance sensor: 

1) Shutter support specification

2) Single-ouch or double-ouch

3) Lead wire length

4) lead tube material

5) Protection tube material

6) Protection tubelength

7) Spring material : ID OD and length

 

Transaction History of the Supplier

Below is the information about the supplier's transactions conducted via Alibaba.com. If you require further details regarding the transaction data, please contact the supplier directly.

Transaction Overview

Transactions

Transaction Details

This supplier has completedtransactions with buyers from .

Shipping Destination
Transaction Value
Transaction Date
Email to this supplier
China (Mainland) | Manufacturer, Trading Company
Supplier Assessments:
The supplier supports Trade Assurance – A free service that protects your orders from payment to delivery.
Supplier's Trade Assurance Limit: US $